Compiled by Harry Seifert, MD
University of Pennsylvania
Copyright (c) 1996 SNACC All Rights Reserved


1. Adams DC, Emerson RG, Heyer EJ, McCormick PC, Carmel PW, Stein BM, Farcy JP, Gallo EJ: Monitoring of intraoperative motor-evoked potentials under conditions of controlled neuromuscular blockade. Anesth Analg 77:913-918, 1993

2. Ashkenaze D, Mudiyam R, Boachie-Adjei O, Gilbert C: Efficacy of spinal cord monitoring in neuromuscular scoliosis. Spine 18:1627-1633, 1993

3. Bennett MH: Effects of compression and ischemia on spinal cord evoked potentials. Exp Neurol 80:508-519, 1983

4. Chabal C, Jacobson L, Little J: Effects of intrathecal fentanyl and lidocaine on somatosensory evoked potentials, the H-reflex, and clinical responses. Anesth Analg 67:509-513, 1988

*5. Chatrian GE, Berger S, Wirch AL: Discrepancy between intraoperative SSEP and postoperative function. J Neurosurg 69:450-454, 1988

*6. Cohen AR, Young W, Ransohoff J: Intraspinal localization of the somatosensory evoked potential. Neurosurgery 9:157-162, 1981

7. Dasmahapatra HK, Coles JG, Taylor MJ, Cass D, Couper G, Adler S, Burrows F, Sherret H, Trusler GA, Williams WG: Identification of risk factors for spinal cord ischemia by the use of monitoring of somatosensory evoked potentials during coarctation repair. Circulation 76(supp III):III14-III18, 1987

8. Dorfman LJ, Perkash I, Bosley T, Cummins KL: Use of cerebral evoked potentials to evaluate spinal somatosensory function in patients with traumatic and surgical myelopathies. J Neurosurg 52:654-660, 1980

9 Erwin CW, Erwin AC: Up and down the spinal cord: intraoperative monitoring of sensory and motor spinal cord pathways. J Clin Neurophysiol 10:425-436, 1993

10. Friedman WA: Somatosensory evoked potentials in neurosurgery. Clin Neurosurg 34:187- 238, 1988

11. Gilmore R: The use of somatosensory evoked potentials in infants and children. J Child Neurol 4:3-19, 1989

12. Grundy BL: Intraoperative monitoring of sensory-evoked potentials. Anesth 58:72-87, 1983

13. Harper CM, Nelson KR: Intraoperative electrophysiologic monitoring in children. J Clin Neurophysiol 9:342-356, 1992

*14. Kalkman CJ, Drummond JC, Hoi SU: Severe sensory deficits with preserved motor function after removal of a spinal cord arteriovenous malformation: correlation with simultaneously recorded somatosensory and motor evoked potentials. Anesth Analg 78:165-168, 1994

*15. Kalkman CJ, Drummond JC, Ribberink AA, et al: Effects of propofol, etomidate, midazolam, and fentanyl on motor evoked responses to transcranial electrical or magnetic stimulation in humans. Anesthesiology 76:502-509, 1992

16. Laschinger JC, Cunningham JN, Cooper MM, Baumann FG, Spencer FC: Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. I. Relationship of aortic cross-clamp duration, changes in somatosensory evoked potentials, and incidence of neurologic dysfunction. J Thorac Cardiovasc Surg 94:260-265, 1987

*17. Lee WY, Hou WY, Yang LH, Lin SM: Intraoperative monitoring of motor function by magnetic motor evoked potentials. Neurosurgery 36:493-500, 1993

18. Levy WJ: The electrophysiological monitoring of motor pathways. Clin Neurosurg 34:239- 267, 1988

19. Maeda S, Miyamoto T, Murata H, Yamashita K: Prevention of spinal cord ischemia by monitoring spinal cord perfusion pressure and somatosensory evoked potentials. J Cardiovasc Surg 30:565-571, 1989

*20. McPherson RW, Sell B, Traystman RJ: Effects of thiopental, fentanyl, and etomidate on upper extremity somatosensory evoked potentials in humans. Anesthesiology 65:584-589, 1986

21. Nash CL, Brown RH: Spinal cord monitoring. J Bone Joint Surg 71:627-630, 1989

22. North RB, Drenger B, Beattie C, McPherson RW, Parker S, Reitz BA, Williams GM: Monitoring of spinal cord stimulation evoked potentials during thoracoabdominal aneurysm surgery. Neurosurg 28:325-330, 1991

*23. Peterson DO, Drummond JC, Todd MM: Effects of halothane, enflurane, isoflurane, and nitrous oxide on somatosensory evoked potentials in humans. Anesthesiology 65:35-40, 1986

24. Reuter DG, Tacker WA Jr, Badylak SF, Voorhees WD 3d, Konrad PE: Correlation of motor-evoked potential response to ischemic spinal cord damage. J Thorac Cardiovasc Surg 104:262-272, 1992

25. Schramm J, Kurthen M: Recent developments in neurosurgical spinal cord monitoring. Paraplegia 30:609-616, 1992

26. Stuhmeier KD, Grabitz K, Mainzer B, Sandmann W, Tarnow J: Use of the electrospinogram for predicting harmful spinal cord ischemia during repair of thoracic or thoracoabdominal aortic aneurysms. Anesthesiology 79:1170-1176, 1993

27. Svensson LG, Patel V, Robinson MF, Ueda T, Toehm JO Jr, Crawford ES: Influence of preservation or perfusion of intraoperatively identified spinal cord blood supply on spinal motor evoked potentials and paraplegia after aortic surgery. J Vasc Surg 13:355-365, 1991

*28. Zentner J, Albrecht T, Heuser D: Influence of halothane, enflurane, and isoflurane on motor evoked potentials. Neurosurgery 31:298-305, 1992

29. Zigler J, Rockowitz N, Capen C, Nelson R, Waters R: Posterior cervical fusion with local anesthesia. The awake patient as the ultimate spinal cord monitor. Spine 12:206-208, 1987